Uni Care House wires

Uni Care House wires

Product Details:

X

Product Description

Uni Care House wires

V-Marc FRLS/ZHFR House Wires
The Company now intruduce a rang of V-Marc wires for various applications. These wires conform to IS 694-1990. V-Marc wire are made of bright, plain annealed copper conductor, as per IS: 8130-1984. These wires are suitable for all Commercial & Domestic wiring applications. The House Wires have uniform diameter and are available in standard length of 90 meter coils.

Special Insulation Wires
  • Flame Retardant Low Smoke (FRLS) wire: These wire are made of special insulation material with higher oxygen and temperature indices and lower smoke density rating and acid gas generation. This insulation retards flame propagation in buildings and industries. This insulation generates low smokes under fire condition.
  • Zero Halogen Flame Retardant (ZHFR) wire: The insulation is free from halogen, thus preventing emission of corrosive gases under conditions of fire. These wires are primarily used where critical control supply is essential during a fire-lifts, fire alarms, hospitals etc.
  • Oxygen Index is use as a measure of flame retardant property of the insulating material. The oxygen index indicates percentage of oxygen required for supporting combustion of insulating material at room temperature. The ordinary PVC insulation has an Oxygen Index of 23% Higher Oxygen Index is desirable.
  • Temperature Index indicates the temperature at which normal oxygen content of 21% in air will support combustion of insulating material. Higher temperature index is better.
  • Smoke Density indicates the loss of light transmission from insulation material under fire. Lower the smoke density, the better is the visibility & efficacy of fire fighting operations.
  • Acid Gas Generation indicates the amount of hydrochloric acid gas evolved from insulation of cable under fire. Lower Acid Gas Generation is desirable.
Characteristics
Standard
Typical Value
Typical Value
Oxygen Index
ASTM-D 2863
>29%
>29%
Temperature Index
ASTM-D 2863
>250°C
>250°C
Smoke Density Rating
ASTM-D 2843
<60%
<60%
Acid Gas Generation
IEC 754-1
Max. 20%
Max. 20%

Nominal area of conductor
Number/Nom. Dia of Wire
Thickness of Insulation (Nom)
Approx. Overall Diameter
Current carrying capacity 2 cables, single phase In cuduit/Unenclose-clipped Trunking directly to surface or on cable tray

Max Resistance per km at 20°C
Sq. mm
mm
mm
mm
Amp
Amp
Ohms
1.0
14/.3
0.7
2.8
11
12
18.10
1.5
22/.3
0.7
3.1
14
16
12.10
2.5
36/.3
0.8
3.8
19
22
7.41
4.0
56/.3
0.8
4.4
26
29
4.95
6.0
84/.3
0.8
5.0
31
37
3.30